2584820 - 5040A14 air conditioner cooling circuit - check and repair any leaks by tightening fittings

Follow the specified safety instructions (See 5040A - AIR CONDITIONER REFRIGERANT SYSTEM)
1. Use the special Cleaner 134 draining/repressurizing equipment.
Introduce a certain amount of R134a coolant fluid into the system.1. Use a leak detector to identify the area where the leak is coming from.

NameCountry
1Halogen gas (Freon leak detector)1.806.138.000
Drain the fluid and eliminate the leak, tightening any slack connectors or replacing any damaged pipes or components.    Op. 5040A10 AIR CONDITIONING REFRIGERANT CIRCUIT - DRYING AND REPRESSURIZING