244000445 - B02 STARTER MOTOR NOT WORKING

When the key is turned to the ON position, the instruments light up but the starter motor does not turn.
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Turn the key ON and check that the generator comes on (it should then go off when the engine is running)Move on to Step 1The generator does not come on    See table K40 BATTERY CHARGING WARNING LIGHT NOT WORKING
1ELECTRICAL CONNECTION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the connections between battery, ignition switch and starter motor.    See E5010 STARTING AND RECHARINGMove on to Step 2Connections not correctRestore battery connections    See E5010 STARTING AND RECHARING
Earth lead damagedReplace the lead
Lead between battery and starter motor damagedReplace the lead    Op. 5530B26 LEAD BETWEEN BATTERY AND STARTER MOTOR - R+R
2CHECK STARTER MOTOR CONNECTIONSALL OKPROBLEMS ENCOUNTEREDACTION
Check connections between:

  • battery, ignition switch and motor control relay;
  • battery and motor control relay;
  • relay, switch for remote control switch and starter motor.
    See E5010 STARTING AND RECHARING
Move on to Step 3Connections not correctRepair the connections    See E5010 STARTING AND RECHARING
Relay faultyReplace the relay
Switch faultyReplace the switch
3IGNITION SWITCH CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the condition of the ignition switch and that it is working properlyMove on to Step 4Ignition switch faultRepair or replace the ignition switch    Op. 5520A12 IGNITION SWITCH ASSEMBLY - R R FOR VERSIONS WITH AIR BAG
4CHECK STARTER MOTORALL OKPROBLEMS ENCOUNTEREDACTION
Check the condition of the ignition switch and that it is working properlyEnd of diagnosisFault in starter motorService the starter motor
Non-resettable fault in starter motorReplace the starter motor    Op. 5520B10 STARTER MOTOR - R+R