244000492 - K10 DOORS OPEN CHECK NOT WORKING

The warning light does not come on when the doors are opened.
Several warning lights fail to come on if the instrument panel supply is faulty
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CONTINUITY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check door switches are correctly connected between earth point and control panelCheck the individual electrical branch if a warning light does not come on when a single door is opened    See E4010 INSTRUMENT PANELMove on to Step1. Connections not correct.1. Restore the electrical connection    See E4010 INSTRUMENT PANEL
2. Switch poorly positioned or defective.2. Repair or replace the switch
2CHECK ON CORRECT OPERATION OF INSTRUMENT PANELALL OKPROBLEMS ENCOUNTEREDACTION
Check the correct operation of the door open indicator on the instrument panelMove on to StepInstrument panel defectiveReplace instrument panel    Op. 5560B10 ANALOGUE CONTROL PANEL - R+R
3CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present