244000495 - K40 BATTERY CHARGING WARNING LIGHT NOT WORKING

The warning light does not come on at key on.
Several warning lights fail to come on if the instrument panel supply is faulty
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CONTINUITY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity of the connections between alternator and instrument panel and control panel warning light internal circuit continuity    See E4010 INSTRUMENT PANELMove on to Step1. Connections not correct1. Restore the connections    See E4010 INSTRUMENT PANEL
2. Instrument panel defective2. Replace instrument panel    Op. 5560B10 ANALOGUE CONTROL PANEL - R+R
2ALTERNATOR CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check alternator earth signal    See E4010 INSTRUMENT PANELMove on to StepAlternator defectiveService or replace the alternator
3CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present