244000508 - N04 POWER POINT NOT WORKING

Power point not working.
cigar lighter works.
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity of the positive wiring between the power point and the intermediate junction connection    See E3070 CIGAR LIGHTER / CURRENT SOCKETMove on to StepWiring brokenRepair wiring    See E3070 CIGAR LIGHTER / CURRENT SOCKET
2ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity of the earth wiring between the power point and the earth connection    See E3070 CIGAR LIGHTER / CURRENT SOCKETMove on to StepWiring brokenRepair wiring    See E3070 CIGAR LIGHTER / CURRENT SOCKET
3CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check the power point is working properlyPower point not workingReplace power point    Op. 7065C72 FRONT CIGAR LIGHTER SOCKET/POWER POINT - FASTEN