244000764 - 1042A44 CNG RECHARGE PIPE CONNECTION SLEEVE - R R

Removing ( Refitting ) Position the vehicle on the lift.Proceed with draining the high pressure circuit following the instructions in the specific operation:    Op. 1042A02 METHANE SYSTEM SAFETY SET UP1. Release the safety pipe.2. Undo the connectors (2a) and remove the hose (2b).
Refitting ( Removing ) Fit the hose and tighten the connectors.
Value daNmFasteningComponentØ  
-2.8Connector--
Position the safety pipe.Move the CNG cut-off solenoids to open position by hand and check system is efficient.Remove the vehicle from the lift.