244000531 - 1042AA CHECK OPERATION OF COIL FOR METHANE CUT OUT SOLENOID VALVE ON CANISTER

Disconnect the electrical connection for the solenoid valve on the methane canister and check that the coil winding resistance is 11.50 Ohm ± 20 % at 20°C.