DUCATO
2.0 16V
PROCEDURES
10 ENGINE UNIT
1042 METHANE GAS CANNISTER AND TUBES
1042A METHANE GAS CANNISTER AND TUBES FOR RE-CHARGING
1042A20 INJECTION SYSTEM SOLENOID ON CYLINDER R R
244000757 - 1042A20 INJECTION SYSTEM SOLENOID ON CYLINDER R R
Removing
(
Refitting
)
Position the vehicle on the lift.
Op. 1042E60 CNG CYLINDER UNIT PROTECTION SEAL - R R
Op. 1042A02 METHANE SYSTEM SAFETY SET UP
Proceed with draining the high pressure circuit following the instructions in the specific operation:
Op. 1042A50 PIPE (1) CONNECTING CNG RECHARGING SYSTEM SOLENOIDS - R R
[All]
Op. 1042A16 CNG CYLINDER UNIT - R R
1. Undo the solenoid valve and remove it from the housing on the canister.
Refitting
(
Removing
)
Fit the CNG cut out solenoid valve and tighten it to the canister.
Op. 1042A16 CNG CYLINDER UNIT - R R
Op. 1042A50 PIPE (1) CONNECTING CNG RECHARGING SYSTEM SOLENOIDS - R R
[All]
Op. 1042E60 CNG CYLINDER UNIT PROTECTION SEAL - R R
Move the CNG cut-off solenoids to open position by hand and check system is efficient.
Remove the vehicle from the lift.