244002662 - 1043B22 FITTING WITH PRESSURE SENSOR ON DELIVERY PIPE TO INJECTORS - R.R.

Removing ( Refitting ) Drain the supply pipe from the supply solenoid valve to the injectors, following the instructions in the procedure:    Op. 1043A02 LPG SYSTEM LINES PIPE DRAINING OPERATIONSDisconnect the negative battery terminal.1. Disconnect the pressure sensor electrical connector.
DescriptionConnector
1LPG pressure sensorK053
2. Undo the connector for the flexible supply pipe to the injectors on the intermediate block.Loosen the connectors for the rigid supply pipe on the solenoid valve and on the intermediate block.3. Undo the nuts fixing the intermediate connector to the mounting bracket.4. Undo the connector (4a) for the rigid supply pipe for the solenoid valve; then remove the intermediate block (4b) complete with LPG pressure sensor.
Refitting ( Removing ) Position the intermediate block complete with LPG pressure sensor and secure it to the mounting bracket without tightening the retaining nuts.Tighten the connector for the rigid supply pipe for the solenoid valve.
Value daNmFasteningComponentØ  
-2.5Connectoron the intermediate blockM12 X 1
Tighten the connector for the rigid supply pipe to the solenoid valve to torque.
Value daNmFasteningComponentØ  
-1.5Connectoron the supply solenoid valveM10 X 1
Tighten the nuts fixing the intermediate block to the mounting bracket to torque.
Value daNmFasteningComponentØ  
-0.9Nutto the mounting bracketM6
Tighten the connector for the flexible supply pipe to the injectors to the recommended torque.
Value daNmFasteningComponentØ  
-7Connectoron the supply line intermediate blockM18 X 1.5
Connect the LPG pressure sensor electrical connector.
DescriptionConnector
-LPG pressure sensorK053
    Op. 1043A04 GPL SYSTEM AND PIPES CHECK FOR LEAKSConnect the negative battery terminal.