244002663 - 1043B42 PRESSURE REGULATON FOR GPL SUPPLY COMPLETE WITH DELIVERY AND RETURN LINES FROM INTERMEDIATE CONNECTOR R R

Removing ( Refitting ) Drain the LPG supply and return pipes from the tank to the solenoid valves / G4-G5 and the supply pipe to the injectors,following the instructions in the procedure:    Op. 1043A02 LPG SYSTEM LINES PIPE DRAINING OPERATIONSPosition the vehicle on the lift.Disconnect the negative battery terminal.1. Undo the nuts (1a) and move the engine coolant reservoir (1a) away from the work area, leaving the pipes connected.
1. Undo the connectors (1a) and disconnect the LPG supply and return pipes (1b) from the tank.
Mark the exact fitting position of the pipes to prevent them being incorrectly refitted.
1. Undo the connectors (1a) and disconnect the LPG supply and return pipes (1b) to the injectors.
Mark the exact fitting position of the pipes to prevent them being incorrectly refitted.
2. Disconnect the electrical connection frrom the pressure sensor.
DescriptionConnector
2LPG pressure sensorK053
3. Disconnect the electrical connections for the LPG cut out solenoid valves.
DescriptionConnector
3LPG cut out solenoid valvesL063
Move the electrical wiring aside.
1. Undo the fixing nuts (1a) on the mounting bracket (1b).2. Remove the solenoid valve assembly / G4-G5 complete with pipes.
Refitting ( Removing ) Fit the solenoid valve assembly / G4-G5 complete with pipes and secure it to the mounting bracket tightening the nuts to the recommended torque.
Value daNmFasteningComponentØ  
-1.1NutM6 X 1
Connect the electrical connections for the LPG cut out solenoid valves.
DescriptionConnector
-LPG cut out solenoid valvesL063
Connect the electrical connection for the pressure sensor.
DescriptionConnector
-LPG pressure sensorK053
Fit the LPG supply and return pipes to the injectors ensuring they are in the position marked on their removal.Tighten the connectors to the recommended torque.
Value daNmFasteningComponentØ  
-7ConnectorM18 X 1.5
Fit the LPG supply and return pipes from the tank ensuring they are in the position marked on their removal.Tighten the connectors to the recommended torque.
Value daNmFasteningComponentØ  
-1.5ConnectorM10 X 1
    Op. 1043A04 GPL SYSTEM AND PIPES CHECK FOR LEAKSPosition the engine coolant reservoir and secure it using the nuts.Connect the negative battery terminal.Remove the vehicle from the lift.