244002677 - 1043B47 DELIVERY OR RETURN (ONE) SOLENOID VALVE - R.R.

Removing ( Refitting ) Drain the return pipe from the injectors to the return solenoid valve, following the instructions in the procedure:    Op. 1043A02 LPG SYSTEM LINES PIPE DRAINING OPERATIONSDisconnect the negative battery terminal.1. Undo the nuts (1a) and move the engine coolant reservoir (1a) away from the work area, leaving the pipes connected.
1. Disconnect the return solenoid valve electrical connector.
DescriptionConnector
1LPG cut out solenoid valvesL063
2. Disconnect the connector for the rigid return pipe to the intermediate block.3. Disconnect the connector for the LPG rigid return pipe to the tank to the solenoid valve.4. Undo the nuts (4a) and remove the solenoid valve (4b) complete with rigid pipe.At the bench, separate the rigid pipe from the solenoid valve.
Proceed in the same way for the removal of the LPG supply solenoid valve.
Refitting ( Removing ) At the bench, screw in the connector for the rigid pipe on the solenoid valve without tightening it.Position the solenoid valve on the mounting bracket and fit the connector for the rigid pipe on the intermediate block.Tighten the nuts fixing the solenoid valve to the mounting bracket to torque.
Value daNmFasteningComponentØ  
-0.9Nutmounting bracketM6
Tighten the connector for the rigid return pipe to the solenoid valve to the recommended torque.
Value daNmFasteningComponentØ  
-1.5Connectoron the return solenoid valveM10 X 1
Tighten the connector for the rigid return pipe to the intermediate block to the recommended torque.
Value daNmFasteningComponentØ  
-2.5Connectoron the intermediate blockM12 X 1
Screw in and tighten the connector for the LPG rigid return pipe to the tank to the recommended torque.
Value daNmFasteningComponentØ  
-1.5Connectoron the solenoid valveM10 X 1
Connect the return solenoid valve electrical connector.
DescriptionConnector
-LPG cut out solenoid valvesL063
Position the engine coolant reservoir and secure it using the nuts.    Op. 1043A04 GPL SYSTEM AND PIPES CHECK FOR LEAKSConnect the negative battery terminal.