244000610 - 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE

Follow the recommended safety instructions (see 0010 - Attention/Warnings).
- Let the engine run with the air conditioning on for 10 - 15 minutes.- Switch off the engine.1. Connect the pressurizing and draining pipes (1a) for the drainage equipment (1b) to the valves on the air conditioning system high pressure and low pressure pipes.
To improve safety the rapid connectors for the equipment connecting pipes have different diameters and are different colours: the low pressure side is larger and blue, whilst the high pressure side is smaller and red.
- Start the procedure for draining the refrigerant fluid, following the instructions in the equipment manual.- Whilst draining the system the compressor fluid that comes out collects in a special container.
The fluid is extremely hygroscopic: avoid leaving the containers open.
- Refill the system with exactly the same amount of fluid indicated on the container.
DescriptionQty.ComponentTypeClassification
.--AIR CONDITIONING SYSTEMOilSP 20
- If some of the components are being replaced, the following amount of oil must be added for each of the replaced components:- Drier filter: 15 cm3- Pipes: 5 cm3/m- Evaporator: 40 cm3- Condenser: 40 cm3- If there are accidental breaks that cause the "rapid" draining of the system (in less than 5 minutes) then the exact amount of fluid that comes out cannot be determined because the high pressure may cause seepage. Add the following recommended amount of oil 75 cm3.- Start the procedure for repressurizing the refrigerant fluid, following the instructions in the equipment manual.- Add the recommended quantity of refrigerant fluid.
DescriptionQty.ComponentTypeClassification
.R134a800 ± 40 gAIR CONDITIONING CIRCUITFluid-
DescriptionQty.ComponentTypeClassification
.R134a1000 ± 40 gAIR CONDITIONING CIRCUITFluid-
DescriptionQty.ComponentTypeClassification
.R134a900 ± 25 gAIR CONDITIONING CIRCUITFluid-
- In the case of damage to the compressor or other system components or following prolonged exposure of the pipes to the air (more than 6 hours) the WASHING procedure must be carried out as follows.- Clean the pipes connected to the compressor using a jet of air.
Use filtered air to prevent the introduction of foreign bodies into the system.
- Connect the (drained) system to the repressurizing equipment.- Introduce the recommended quantity of refrigerant fluid at the high pressure side.- Collect the refrigerant fluid at the low pressure side.- Repeat the introduction and collection of fluid.- Proceed with draining and repressurizing the system as illustrated previously.
If the system is WASHED the entire amount of compressor oil in the system will be removed.
- Refill the system with the recommended amount of oil.
DescriptionQty.ComponentTypeClassification
.--AIR CONDITIONING SYSTEMOilSP 20