244000950 - 1088C40 THERMOSTAT- R + R

Removing ( Refitting )     Op. 0010T20 COOLANT CHECK DENSITY AND TOP UP IF NECESSARY See in Op. 1048A10 See in Op. 1048A21 See in Op. 1048B22 See in Op. 1048B14 See in Op. 1016A10 See in Op. 1088D14 See in Op. 1088D101. Disconnect the electrical connection (1a) for the sender unit and the electrical connection (1b) for the sensor.
DescriptionConnector
1aCoolant temperature sending unit (for instrument panel)K035
DescriptionConnector
1bEngine coolant temperature sensor/sender unitK036
2. Release the coolant recirculation pipe.3. Release the additional heater pipe.4. Release the hose for the rigid pipe from the thermostat.5. Release the hoses for the water/oil heat exchanger.6. Undo the fixing nuts and bolts (6a) and remove the thermostat.
Refitting ( Removing ) - Fit a new seal.- Position the thermostat on the cylinder head and tighten the fixing nuts and bolts, checking the torque.
Value - daNmFasteningComponentØ  
.1,8BoltTHERMOSTATM8
- Connect the electrical connections at the thermostat.
DescriptionConnector
.Coolant temperature sending unit (for instrument panel)K035
DescriptionConnector
.Engine coolant temperature sensor/sender unitK036
- Fit the water/oil heat exchanger pipes and the hose for the rigid pipe to the thermostat.- Fit the coolant recirculation pipe and the additional heater pipe to the thermostat. See in Op. 1088D10 See in Op. 1088D14 See in Op. 1016A10 See in Op. 1048B14 See in Op. 1048B22 See in Op. 1048A21 See in Op. 1048A10    Op. 0010T20 COOLANT CHECK DENSITY AND TOP UP IF NECESSARY