244001262 - 5020M86 FAN FOR ADDITIONAL HEATER UNIT - R.R.

Removing ( Refitting ) - Disconnect the negative battery terminal.    Op. 5020M10 INDEPENDENT HEATER UNIT - R R1. At the bench, disconnect the inlet pipe loosening the retaining bands.
1. Remove the electrical connection protective cover.2. Disconnect the electrical connectors.
1. Undo the bolts (1a) fixing the water pump bracket (1b).- Remove the band fastening the flexible pipe to the pump.2. Remove the water pump.
1. Undo the bolts fixing the fan assembly.2. Remove the fan assembly.
Refitting ( Removing ) - Fasten the fan assembly to the independent heater casing tightening the fixing bolts.- Place the water pump in the correct fitting position.- Fit the flexible pipe on the pump and secure it using the retaining band.- Fasten the water pump to the independent heater casing tightening the bolt fixing the pump retaining band.- Connect the electrical connectors and secure the protective cover.- Fasten the air inlet pipe to the heater using the retaining bands.    Op. 5020M10 INDEPENDENT HEATER UNIT - R R- Connect the negative battery terminal.    Op. 0010T20 COOLANT CHECK DENSITY AND TOP UP IF NECESSARY