244001275 - 5040A54 PIPE FROM DEHYDRATING FILTER TO EXPANSION VALVE - R+R

Removing ( Refitting )     Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE- Disconnect the negative battery terminal.1. Undo the bolt fixing the pipe to the drier filter.2. Undo the bolt fixing the pipe to the expansion valve.- Disconnect the electrical connector for the multi-stage pressure switch.
DescriptionConnector
.4 stage pressure switchK010
3. Remove the pipe from the drier filter to the expansion valve.
- At the bench, separate the pipe from the multi-stage pressure switch. Refitting ( Removing ) - Secure the multi-stage pressure switch to the pipe.- Connect the pipe to the the expansion valve tightening the fixing bolts.- Connect the pipe to the the drier filter tightening the fixing bolts.- Connect the electrical connector for the multi-stage pressure switch.
DescriptionConnector
.4 stage pressure switchK010
- Secure the pipe to the mounting bracket, tightening the nut.- Connect the negative battery terminal.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE