244001276 - 5040A58 PIPE FROM EXPANSION VALVE TO COMPRESSOR - R+R

Removing ( Refitting )     Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGEDisconnect the negative battery terminal.    Op. 7055B54 UNDER-ENGINE GUARD - R R. Unscrew the connectors of the delivery and return pipes on the compressor.. Release the pipes from the bracket.Unscrew the bolt securing the pipe to the expansion valve.1. Remove the pipe from the compressor to the expansion valve.
Refitting ( Removing ) Connect the pipe to the expansion valve and tighten the bolt to torque.Connect the delivery and return pipes to the compressor and tighten the connectors to the specified torque.
Valore daNmFasteningComponentØ  
.4,0ConnectorEXPANSION VALVE PIPE / COMPRESSOR (A.C.)-
Valore daNmFasteningComponentØ  
.4,0ConnectorPIPE COMPRESSOR/CONDENSER (A.C.)-
Secure the pipes to the bracket and tighten the nut.    Op. 7055B54 UNDER-ENGINE GUARD - R RConnect the negative battery terminal.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE