The power supplies to engine fans N011 and N012 are governed by relays T06 and T07, housed in engine bay junction unit B001. The relay supply line, direct from the battery, is protected by fuses F06 and F07, also housed in the control unit.On the basis of data supplied by engine coolant temperature sensor K036, engine management unit M010 excites the relay coil via a negative signal and thus supplies the fans with power.