312001726 - 5510OA IGNITION COIL RESISTANCE CHECK

Connect to the terminals of the primary winding circuit across pins 1 -2, 1 -3, 1 -4 and 1 -5, and check that the resistance readings are 0.5 Ohm ± 10% at 23°C ± 3°C
Ignition coil connector