312000162 - F030 ANTI-SLIP FUNCTION NOT WORKING - ASR

The front wheels slip with sudden acceleration, even with the ASR warning light flashing in the panel
Test results
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner Plus or Smart diagnostic equipment to the diagnostic connector:- check that there are no faults in the ABS control unit;- check the plausibility of all the parametersMove on to Step 21. Presence of errors in the control unit.2. No communication with the control unit1. Proceed as instructed by the diagnostic equipment2. Restore the connection between the ABS control unit and the diagnostic connector    See E7020 ABS
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the diagnostic equipment connected, carry out the active diagnosis of:- pump motor;- solenoidsMove on to Step 3Pump and/or solenoids faultyReplace the ABS electronic control unit electrohydraulic unit    Op. 3340A12 ABS HYDRAULIC AND ELECTRONIC CONTROL UNIT - R.R.
3FRONT PAD TYPE AND SURFACE CHECKAll OKProblems encounteredOperation
Check:- the condition of the pad brake surfaces;- type of padsMove on to Step 41. Brake surfaces vitrified or show traces of oil or grease2. Front pads damaged or not the correct type1. Clean again and remove the causes of the fault2. Replace the front pads    Op. 3310A60 FRONT BRAKE PADS - REPLACE
4FRONT DISCS CHECKAll OKProblems encounteredOperation
Check the condition of the front brake discsMove on to Step 5Front discs worn or damagedReplace the front discs    Op. 3310A48 FRONT BRAKE DISC (ONE), LEFT OR RIGHT - R.R
5FRONT BRAKE CALLIPER CHECKAll OKProblems encounteredOperation
Check the sliding of the front brake calliper control pistonsMove on to Step 6Front calliper pistons seizedReplace the front brake callipers    Op. 3310A30 FRONT BRAKE CALIPER (ONE) - R.R
6PIPE / HOSE AND BRAKE BLEEDING CHECKAll OKProblems encounteredOperation
Visually inspect that there are no bends or constrictions in the brake pipes, bleed the system and check that the fluid comes out evenly from the bleed screwsEnd of diagnosisBends or constrictions present, the fluid does not come out evenlyReplace the section of pipe affected by the problem