312000221 - I005 DIPPED HEADLAMPS NOT WORKING

Neither of the main beam headlamps works under any condition N.B. The dipped beam headlights are managed by the Body Computer Node The lights can be switched on/off using the following controls:1. Specific command (from the Exterior Lights Control on the steering column)2. Follow me home command
Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Activate the appropriate command and check whether the warning light on the dashboard comes on.Move on to Step 2The warning light is not activated.Move on to Step 1
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner diagnostic equipment and check that there are no errors in the Body Computer ambientMove on to Step 2Presence of errorsContinue as instructed by the diagnostic equipment
2ACTIVE DIAGNOSIS CHECKAll OKProblems encounteredOperation
With the Examiner in the Body Computer mode check that the dipped headlights are correctly activated in Active Diagnosis.End of diagnosis1. Impossible to activate one of the dipped headlights because the bulb is broken2. Impossible to activate one of the dipped headlights because the wiring is broken3. Impossible to activate both lights1.Replace the defective bulb.2.Restore correct wiring.3. Move on to Step 3
3DIPPED HEADLIGHTS ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
Check that the steering column switch unit lights are working properlyCheck the continuity of the wiring between the steering column switch unit and the Body Computer and between the Body Computer and the lightsCheck the operation of the dipped headlights relay in the dashboard junction unit    See E2011 DIPPED HEADLAMPS Move on to Step 41. Steering column switch unit defective2. Wiring broken3. Relay defective1. Replace the steering column switch unit    Op. 5550A10 STALK UNIT ASSEMBLY - R+R 2. Restore correct wiring3. Replace the relay.
4BODY COMPUTER CORRECT OPERATION CHECKAll OKProblems encounteredOperation
Check that the body computer is working properly.End of diagnosisBody Computer defectiveReplace body computer    Op. 5505A32 BODY COMPUTER - R.R