312000699 - N009 TRIP COMPUTER WRONG READINGS

the trip computer indicates incorrect fuel consumption
Test results
1CHECK USING THE EXAMINERAll OKProblems encounteredOperation

Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:

  • No control units inactive
  • No control units with faulty CAN line
Move on to Step 2Control units with CAN faulty/Not activatedContinue as instructed by the diagnostic equipment
2TRIP COMPUTER SIGNALS CHECKAll OKProblems encounteredOperation
Check the speed signal is working properly    See E4080 TRIP COMPUTER Check the fuel level gauge is working properlyMove on to Step 31. Speed signal interrupted2.Fuel level signal does not conform3. Level signal interrupted1. Move on to Step 32. Replace fuel level gauge    Op. 1040A70 SUBMERGED PUMP ASSEMBLY COMPLETE WITH LEVEL GAUGE CONTROL - R + R 3. Restore the correct continuity
3CHECK USING THE EXAMINERAll OKProblems encounteredOperation
Connect to the ABS control unit and check that there are no errorsEnd of diagnosisPresence of errorsContinue as instructed by the diagnostic equipment