312002386 - 1064B38 WASTE GATE SUPERCHARGING PRESSURE ADJUSTMENT SOLENOID VALVE - R.R.

Removing ( Refitting ) - Disconnect the negative battery terminal.
DescriptionConnector
-BATTERY    See A001 BATTERY
1. Disconnect the electrical connection for the turbocharging adjustment solenoid valve.
DescriptionConnector
1WASTEGATE SOLENOID    See L037 WASTE GATE SOLENOID VALVE
2. Undo the nut securing the bracket to battery drip-tray.
1. Disconnect air pipes (1a) and remove solenoid (1b).
- At the bench, tighten the main bolts and separate the turbocharging pressure adjustment solenoid mounting bracket. Refitting ( Removing ) - At the bench, fit the turbocharging pressure adjustment solenoid on the mounting bracket and tighten the main bolts.- Connect the vacuum air pipes to the solenoid.- Fit the solenoid bracket on the battery drip-tray and tighten the nut. 1. Connect the electrical connection for the turbocharging adjustment solenoid valve.
DescriptionConnector
1WASTEGATE SOLENOID    See L037 WASTE GATE SOLENOID VALVE
- Connect the negative battery terminal.
DescriptionConnector
-BATTERY    See A001 BATTERY