312000592 - 1060GR FUEL PRESSURE SENSOR ON RAIL OPERATION CHECK

Power supply check

  • Turn the ignition key to the MAR position
  • Connect the positive probe of an Examiner in Voltmeter mode to terminal 3 of the sensor and the negative probe to terminal 1 of the sensor earth
  • With the ignition on, check that the voltage measured is around 5 Volts,
Signal check

  • Connect the positive probe of an Examiner in Voltmeter mode to terminal 2 of the sensor and the negative probe to terminal 1 of the sensor earth
  • Start the engine and check for the presence of a voltage signal whose value is directly proportional to the fuel pressure as illustrated in the attached graph
PINDESCRIPTIONTYPE OF SIGNAL
1earthearth
2sensor outputanalogue output
3power supply5 Volt intake