312001718 - 5040OB AIR CONDITIONING SYSTEM OPERATION CHECK (PRESSURE)

Do not check the air conditioning system in the immediate vicinity of any walls (do it at a distance of approximately 2 m.), in order to ensure the condenser has sufficient air circulation.
STEPCHECK TO BE PERFORMEDREMEDIAL ACTION IF THE CHECK IS NOT OK
1Connect the air conditioning system repressurizing station.Read the value on the high pressure gauge and compare it with the A/C (air conditioning) pressure parameter, checking that the two values more or less coincide.Carry out the    See Test 5040BA MULTI-STAGE PRESSURE SWITCH/LINEAR SENSOR OPERATION CHECK
2Check that the condenser is not blocked with dirtClean the condenser fins or repair the radiator
3Carry out the    See Test 5040AB REFRIGERANT CIRCUIT CHECK