312002059 - 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE
|  | Follow the safety instructions | 

|  | For safety reasons, the rapid connectors for the station pipes are different diameters for the high and low pressure sides. The diameter of the high pressure pipe is smaller than the one for the low pressure pipe. | 

|  | The fluid is extremely hygroscopic: avoid leaving the containers open. | 

| Component | Type | Description | Classification | Quantity | Validity | 
|---|---|---|---|---|---|
| DENSO SCS06 compressor | Oil | ND8 | - | - | all versions | 
In the case of operations that involve replacing some of the system components, special oil must be added, in the quantities indicated below, before refitting:
- Pipes: 5 cm3/m;
- Evaporator: 40 cm3;
- Condenser with integrated filter: 50 cm3;
|  | If there are accidental breaks that cause the "rapid" draining of the system (in less than 5 minutes) then the exact amount of fluid that comes out cannot be determined because the high pressure may cause seepage. Add the following recommended amount of oil 75 cm3. | 
| Component | Type | Description | Classification | Quantity | Validity | 
|---|---|---|---|---|---|
| Air conditioning system circuit | Fluid | R134a | - | 500 g ± 40 g | all versions | 
|  | Use filtered air to prevent the introduction of foreign bodies into the system. |