312002488 - 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R
 Removing
		(
		Refitting
Removing
		(
		Refitting )
		)
	|  | Before working on the Air Bag system, follow the safety instructions for working on the system very carefully. | 
| Description | Connector | |
|---|---|---|
| - | Battery | See A001 BATTERY | 
| Description | Connector | |
|---|---|---|
| 2 | Outside air/recirculation intake flap actuator | See N082 OUTSIDE / RECIRCULATION AIR INTAKE FLAP ACTUATOR | 

 Refitting
		(
		Removing
Refitting
		(
		Removing )
	1. Place the outside/recirculation air flap actuator in position, taking care to make sure that the gear is in the correct position.2. Tighten the fixing bolts.3. Connect the electrical connection for the recirculation/outside air flap actuator.
		)
	1. Place the outside/recirculation air flap actuator in position, taking care to make sure that the gear is in the correct position.2. Tighten the fixing bolts.3. Connect the electrical connection for the recirculation/outside air flap actuator.| Description | Connector | |
|---|---|---|
| 3 | Outside air/recirculation intake flap actuator | See N082 OUTSIDE / RECIRCULATION AIR INTAKE FLAP ACTUATOR | 

| Description | Connector | |
|---|---|---|
| - | Battery | See A001 BATTERY |