312002938 - P0045 Turbo actuator command

The error is recognized by comparing the control with the feedback (microcontrol diagnosis).The test is carried out if the battery voltage and the main relay are okay and the duty cycle is less than 99% (with detail CA - open circuit or CC GND - short circuit to earth) and more than 1% (with detail CC VBAT - battery voltage short circuit).
Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Check, in the engine compartment junction unit, that relay T7 (the first from the top in the bottom left row) is working properly and that fuse F27 (the fourth from the top in the left row) have not blownMove on to Step 1Relay T7 is brokenReplace the relay
Fuse F27 has blownReplace the fuse, then search for the cause of the problem and eliminate it
1ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
Check the continuity and the insulation of the turbo actuator supply circuit    See E5050 DIESEL ENGINES ELECTRONIC MANAGEMENT Move on to Step 2Connections not correctRestore or, if necessary, replace the wiring
2Turbo actuator replacementAll OKProblems encounteredOperation
Replace the turbo actuator    Op. 1064B38 WASTE GATE SUPERCHARGING PRESSURE ADJUSTMENT SOLENOID VALVE - R.R.and check the fault has disappearedEnd of diagnosisThe fault persistsContact technical service for further information on the problem