312000171 - I034 REVERSING LIGHTS TWO ALWAYS ON

The reversing lights stay on even with reverse disengaged.
Test results
1REVERSING SWITCH CHECKAll OKProblems encounteredOperation
Check operation of reversing switch.Move on to Step 2Switch always closed.Replace the reversing switch    Op. 5550D22 REVERSING LIGHT SWITCH - R+R
2ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation
Check the insulation of the wires in the lead from the switch to the intermediate connection    See E2022 REVERSING LIGHTS Move on to Step 3Wiring short-circuitedRestore correct wiring    See E2022 REVERSING LIGHTS
3ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation
Check the insulation of the wires in the lead from the intermediate connection to the reversing light    See E2022 REVERSING LIGHTS End of diagnosis.Wiring short-circuitedRestore correct wiring    See E2022 REVERSING LIGHTS