312000566 - D032 ELECTRIC FAN COMES ON TOO OFTEN

Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation

Check the following, in order:

  • Correct engine oil level
  • Possible oil leaks
  • Correct coolant level
  • Possible coolant leaks
  • Radiator blocked
Move on to Step 11. Engine oil level not correct2. Oil leaks3. Coolant level not correct4. Coolant leaks5. Radiator blocked1. Adjust oil level2. Eliminate leaks3. Top up level4. Eliminate leaks5. Descale radiator
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner diagnostic equipment to the engine control unit.

Check:

  • that there are no errors in the control unit;
  • parameter plausibility.
Move on to Step 2 for versions with air conditioning onlyMove on to Step 3 for all versions1. Error detected in the control unit2. Parameters not plausible1. Continue following the instructions on the diagnostic equipment2. Continue following the instructions on the diagnostic equipment
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner diagnostic equipment to the climate control system control unit.

Check:

  • that there are no errors in the control unit;
  • parameter plausibility.
Move on to Step 31. Onset of error detected in the control unit.2. Parameters not plausible1. Continue following the instructions on the diagnostic equipment2. Continue following the instructions on the diagnostic equipment
3WATER TEMPERATURE SENSOR CHECKAll OKProblems encounteredOperation
Check that the water temperature sensor is working properly by carrying out the    See Test 1056BC ENGINE COOLANT TEMPERATURE SENSOR OPERATION CHECKMove on to Step 41. Sensor defective2. Sensor wiring connection irregular1. Replace the sensorOp. 1056B50 2. Restore the correct connection.
4WIRING CHECKAll OKProblems encounteredOperation
Check the continuity of the connections between the engine control unit and fuse control unitCheck the fan control relay is working properly    See E5020 ENGINE COOLING Move on to Step 51. Wiring defective2. Relay defective1. Restore the correct wiring.2. Replace the relay
5LINEAR PRESSURE SWITCH CHECKAll OKProblems encounteredOperation
Check the continuity of the wiring between the linear pressure switch and the engine control unitCheck the operation of the linear pressure switchMove on to Step 61. Wiring defective2. Pressure switch defective1. Restore correct wiring.2. Replace the linear pressure switch    Op. 5040B20 AIR CONDITIONING LINEAR PRESSURE TRANSDUCER - R.R.
6THERMOSTAT CHECKAll OKProblems encounteredOperation
Check that the thermostat is working properlyMove on to Step 7Thermostat defectiveReplace the thermostatOp. 1088C40 THERMOSTAT- R + R
7ENGINE CONTROL UNIT CHECKAll OKProblems encounteredOperation
Check that the engine control unit is working properlyEnd of diagnosisEngine management control unit defectiveReplace the engine management control unit    Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R