312000661 - K102 DISPLAY MODULE NO SIGNAL - TO CHECK PANEL

The display module is turned on by the panel at key on and displays information for the user
Test results
1CHECK USING THE EXAMINERAll OKProblems encounteredOperation
Connect an Examiner and check in CAN Information that there are no control units in errorMove on to Step 2Control unit faultyContinue as instructed by the diagnostic equipment
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the diagnostic equipment and check the operation of the display segments at the INSTRUMENT PANEL NODE by activating the Autotest function in active diagnosisEnd of diagnosisOne or more segments do not come onReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R