312000752 - P010 CENTRAL LOCKING NOT WORKING

When the central locking is activated using the mechanical key or from the inside, via the safety knob, the central locking system does not work. N.B.: The door opening/closing command reaches the Body computer node. The latter sends the signal received to the actuators which close/open the side doors, and directly controls the closing of the boot lid.
Test results
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner diagnostic equipment and check:

  • that there are no faults.
Move on to Step 2Presence of errors.Continue following the instructions for the diagnostic equipment.
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the Examiner diagnostic equipment connected to the Body Computer, carry out the active diagnosis for the defective door lock.Move on to Step 3The door does not close/open.Move on to Step 4
3CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner diagnostic equipment, check that the learning of the change of state for the door opening/closing switch is correct.Move on to Step 5The signal for the door opening/closing switch status has not been learnt correctly.Move on to Step 4
4ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
Check the continuity/insulation of the electrical connection between the defective door lock and the Body ComputerCheck the continuity/insulation of the electrical connection between the Body Computer, the dashboard control unit and the defective door lock    See E3040 CENTRAL LOCKING Move on to Step 51. Electrical connection broken or not insulated.2. Defective front door lock1. Restore the electrical connection    See E3040 CENTRAL LOCKING 2. Replace the front door lockOp. 7005N21
5CORRECT LOCK OPERATION CHECKAll OKProblems encounteredOperation
Check that the door locks are working properlyMove on to Step 6Defective front door lockReplace the defective door lockOp. 7005N21
6BODY COMPUTER CORRECT OPERATION CHECKAll OKProblems encounteredOperation
Check that the body computer is working properlyEnd of diagnosis.Body Computer defectiveReplace body computer    Op. 5505A32 BODY COMPUTER - R.R