312000657 - K095 INSTRUMENT PANEL NOT WORKING

With the ignition ON, some of the warning lights are not timed and the instruments are not working with the engine running.
Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation

Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:

  • No control units inactive
  • No faulty control units
  • no control units with faulty CAN
Move on to Step 1Fault on CAN networkContinue following the instructions given by the diagnostic equipment
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner in the Instrument Panel Node mode, check that there are no errors and that the parameters are presentMove on to Step 21. Presence of errors2. Communication with the instrument panel impossible1. Continue following the instructions on the diagnostic instrument2. Move on to Step 2
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correct by carrying out the    See Test 5560BV Check the instrument panel power supplyMove on to Step 31. Supply not correct2. Connection to panel not correctly connected1. Restore correct power supply    See E4010 INSTRUMENT PANEL 2. Fit the connection correctly
3CHECK ON CORRECT OPERATION OF INSTRUMENT PANELAll OKProblems encounteredOperation
Check that the instrument panel is working properlyMove on to Step 4Instrument panel defectiveReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
4BODY COMPUTER CORRECT OPERATION CHECKAll OKProblems encounteredOperation
Check the suppy is correctCheck that the connections are correctly connectedCheck that the Body Computer is working properlyEnd of diagnosis1. Supply not correct2. Connections to the Body Computer not correctly connected3. Body Computer defective1. Restore correct power supply2. Renew the connections3. Replace Body Computer    Op. 5505A32 BODY COMPUTER - R.R