312001721 - 5510CD RPM SENSOR AND COIL OPERATION CHECK

STEPCHECK TO BE PERFORMEDREMEDIAL ACTION IF THE CHECK IS NOT OK
1Sensor resistance checkDisconnect the electrical connection for the control unit side sensor and leave it disconnected.Using an Examiner in Ohmmeter mode, connect the probes between pins 1 and 2 of the sensor. The reading should show a resistance of 1134 to 1386 Ohms at 20°CReplace the rpm sensor    Op. 5510C26 ENGINE RPM SENSOR - R+R
Rpm sensor