323001489 - 5040A40 AIR CONDITIONING CONDENSER - R+R
 Removing
		(
		Refitting
Removing
		(
		Refitting )
		)
	|  | Follow the recommended safety instructions. Op. 5040 AIR CONDITIONING CASING AND COMPONENTS | 
|  | Seal the connectors that have been disconnected using suitable plugs to prevent dampness and impurities from entering the system. | 


 Refitting
		(
		Removing
Refitting
		(
		Removing )
	- Check that the condenser is intact and does not show signs of damage or deposits of dirt on the finned surface.- If removed, refit the drier filter.    Op. 5040A44  AIR CONDITIONING DRIER FILTER/ACCUMULATOR - R+R
		)
	- Check that the condenser is intact and does not show signs of damage or deposits of dirt on the finned surface.- If removed, refit the drier filter.    Op. 5040A44  AIR CONDITIONING DRIER FILTER/ACCUMULATOR - R+R |  | Replace the O-rings on the connectors. | 
|  | Only use green coloured seals that are resistant to R134a coolant. | 
|  | Lubricate the connector threads using anti-freeze. | 
| Component | Fastening | dia | Value (daNm) | Validity | 
|---|---|---|---|---|
| Pipe connector from condenser/filter on right strut | Bolt | M8 | 1.5 ÷ 2.0 | 