323001903 - 1060OA LOW FUEL RETURN PRESSURE CIRCUIT CHECK

Connect the Examiner diagnostic equipment pressure transducer to the return pipe to the tank (1) using the dedicated fitting.Turn the ignition key ONWithin about 5 seconds check that the pressure reading on the Examiner gauge is less than 1 bar.