323001630 - 1064B42 SOLENOID CONTROLLING TURBOCHARGER VANE POSITION ACTUATOR - R.R

Removing ( Refitting ) - Disconnect the negative battery terminal.1. Disconnect the electrical connection for the solenoid valve.
DescriptionConnector
1Turbine variable geometry control solenoid    See L036 TURBINE VARIABLE GEOMETRY CONTROL SOLENOID VALVE
2. Disconnect the solenoid input and output vacuum pipes.3. Undo the bolt and remove the solenoid.
Refitting ( Removing ) - Position the solenoid in its seat and secure to the bracket with a bolt.- Connect the vacuum pipes to the solenoid.- Connect the electrical connection for the solenoid valve.- Connect the negative battery terminal (-).