323000784 - K009 DOORS OPEN CHECK WARNING LIGHT/SYMBOL ON

After the initial test, the light check warning light on the Instrument Panel Node remains on.
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Check that all four doors are properly shut.Move on to Step 1Doors not properly shut.Shut the doors properly.
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner diagnostic equipment check, in Instrument Panel mode, that there are no errors and that the parameters are present.Move on to Step 21. Impossible to connect to the Instrument Panel control unit.2. Presence of errors.1. Move on to Step 2.2. Continue by following the instructions on the diagnostic instrument.
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner check, in the Body Computer Node ambient, that there are no errors and that the door status parameters vary.Move on to Step 4The parameter values do not change.Move on to Step 3
3ELECTRICAL CONNECTION CHECKAll OKProblems encounteredOperation
- Check that the door switches in the geared motors are working properly;- Check the insulation to earth of the connection between the door switches and the Body Computer    See E3040 CENTRAL LOCKING Move on to Step 41. Switches defective2. Wiring with imperfect insulation to earth1. Replace the switches.2. Restore wiring insulation
4ACTIVE DIAGNOSIS CHECKAll OKProblems encounteredOperation
With the Examiner in the Instrument Panel Node ambient check that the doors open check warning light is correctly activated in Active DiagnosisMove on to Step 5The doors open check warning light is not activatedReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
5CORRECT OPERATION CHECKAll OKProblems encounteredOperation
Check that the fault is no longer present.End of diagnosis.The fault persists.Replace Body Computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.