323000799 - K040 BATTERY CHARGING WARNING LIGHT NOT WORKING

The recharging warning light does not come on with the ignition on
Test results
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner diagnostic equipment to the diagnostic socket.Check warning light operation in active diagnosis mode.Move on to Step 2Warning light does not come onReplace the instrument panel    Op. 5560B10 CONTROL PANEL - R+R
2ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation
Check the correct power supply to the body computer and in particular the D+ signal    See Test 5530AA ALTERNATOR TERMINAL D+ VOLTAGE CHECKEnd of diagnosis1. Body Computer power supply incorrect2. D+ signal between alternator and Body Computer interrupted due to defective wiring3. Alternator defective1. Restore correct power supply2. Restore correct wiring3. Replace alternator    Op. 5530A14 ALTERNATOR - R+R FOR VERSIONS WITH AIR CONDITIONOMG