323000825 - K095 INSTRUMENT PANEL NOT WORKING

With the key to MAR, some of the warning lights are not timed and the instruments are not working with the engine running.
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:- No control units inactive;- No faulty control units;- that there are no control units with faulty CAN.Move on to Step 11. Fault on CAN network.2. Communication with the Body Computer impossible.1. Continue following the instructions given by the diagnostic equipment.2. Move on to Step 5
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner diagnostic equipment, check, in Instrument Panel mode, that there are no errors and that the parameters are present.Move on to Step 41. Presence of errors.2. Impossible to initiate communication with the instrument panel.1. Continue by following the instructions on the diagnostic equipment.2. Move on to Step 2
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correct.    See E4010 INSTRUMENT PANEL Move on to Step 3Fault in positive electrical supply and/or earth.Replace defective component (in the case of a fuse, find out what caused it to blow).
3ELECTRICAL CONNECTIONS CHECKAll OKProblems encounteredOperation
Check the electrical connections between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.Move on to Step 4Electrical connections not operational.Renew the correct connections.
4CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using an Examiner, check in Body Computer Node mode that there are no errors.Move on to Step 71. Impossible to connect to the Body Computer control unit.2. Presence of errors.1. Move on to Step 52. Continue by following the instructions on the diagnostic instrument.
5ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Body Computer Node is correct.Move on to Step 6Fault in positive electrical supply and/or earth.Replace defective component (in the case of a fuse, find out what caused it to blow).
6CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Use an Examiner to check the possibility of connection to the Body Computer NodeMove on to Step 7Impossible to connect to the Body Computer control unit.Replace Body Computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.
7CORRECT OPERATION CHECKAll OKProblems encounteredOperation
Check that the fault is no longer present.End of diagnosis.The fault persists.Replace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R