323000826 - K097 CONTROL PANEL POORLY LIT / NOT LIT

Test results
1ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correct.Move on to Step 2Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow)
2ELECTRICAL CONNECTIONS CHECKAll OKProblems encounteredOperation
Check the electrical connections between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.    See E4010 INSTRUMENT PANEL Move on to Step 3Electrical connections not operationalRenew the damaged electrical connections
3ACTIVE DIAGNOSIS CHECKAll OKProblems encounteredOperation
With the Examiner in Instrument Panel Node mode, check that the instrument panel light is correctly activated in Active DiagnosisEnd of diagnosisThe panel lighting does not activateReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R