323001957 - 5040OB AIR CONDITIONING SYSTEM OPERATION CHECK (PRESSURE)

Do not check the air conditioning system in the immediate vicinity of the walls (distance of approximately 2 m) in order to ensure sufficient circulation of air around the condenser.
STEPCHECK TO BE PERFORMEDREMEDIAL ACTION IF THE CHECK IS NOT OK
1Connect the air conditioning system repressurizing station.Read the value on the high pressure gauge and compare it with the A/C (air conditioning) pressure parameter, checking that the two values more or less coincide.    See Test 5040BA CHECK ON OPERATION OF MULTI-STAGE PRESSURE SWITCH/LINEAR SENSOR
2Check that the condenser is not blocked with dirt.Clean the condenser fins or repair the radiator
3    See Test 5040AB REFRIGERANT CIRCUIT CHECK