323002887 - 1064B37 PRESSURIZED AIR RECIRCULATION PIPE FOR WASTE GATE VALVE - R.R.

Removing ( Refitting ) 1. Adjust the retaining clip and remove the waste gate solenoid from the fan mounting.2. Loosen bands (2a) and remove the pressurized air recirculation pipe for waste gate solenoid (2b).
Refitting ( Removing ) - Place the waste gate solenoid pressurized air recirculation pipe in position and tighten the bands.- Place the waste gate solenoid in position and check that the retaining clip is fitted on the fan mounting.