169790 - L01 CLIMATE CONTROL NOT WORKING IN ANY CIRCUMSTANCES

The climate control system will not work when the controls are operated.
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
0PRELIMINARY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check:

  • condition of climate control system fuses (Wiring Diagram ) E6020 AIR CONDITIONING
  • Correct climate control system pressure
Move on to Step 1. Fuses blown.1. Change the blown fuses.
2. Pressure not correct2. Eliminate leaks and top up climate control system to correct level     See in Op. 5040A10 Air conditioning coolant circuit - Drying and Repressurizing
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
With the tester (Examiner or other instrument) connected, check the CAN network information for:

  • no control unit not activated;
  • that there are no faulty control units;
  • no control unit with faulty CAN line;
Move on to Step Presence of faultsContinue following the instructions for the diagnostic equipment
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:

  • that there are no faults in the climate control system node
Move on to Step 1. Presence of faults1. Continue following the instructions for the diagnostic equpiment
2. No dialogue with the control unitMove on to Step
3CHECK CONTINUITYALL OKPROBLEMS ENCOUNTEREDACTION
Check:

  • continuity of serial line K (Wiring Diagram ) E6020 AIR CONDITIONING
Move on to Step Connections not correctRestore the connections (Wiring Diagram ) E6020 AIR CONDITIONING
4CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the climate control system control unit     See in Op. 5040D18 Air conditioning CONTROL UNIT - R.R.