356099 - L15 CLIMATE CONTROL NOT HEATING

The climate control works properly and sends air to both the left and right sides of the passenger compartments according to the pre-set flows, but this air does not ensure the heating required.
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the diagnostic equipment (Examiner or other instruments) connected, check the following information at the CAN network:

  • no control unit not activated;
  • that there are no faulty control units;
  • no control unit with faulty CAN line
Move on to Step 1. Presence of faults1. Continue following the instructions for the diagnostic equipment
2. Climate control system control unit errorMove on to Step
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check:

  • for faults in the climate control system control unit
Move on to Step 1. Error detected in the control unit1. Continue following the instructions for the diagnostic equipment
2. No communication with the control unit2. Restore the connection between the climate control system control unit and the diagnostic connector (Wiring Diagram ) E6020 AIR CONDITIONING
3ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment (Examiner or other instruments) and carry out the active diagnosis of the mixing motorsMove on to Step mixing motor(s) not workingMove on to Step
4CHECK ELECTRICAL CIRCUITALL OKPROBLEMS ENCOUNTEREDACTION
Check the condition of the electrical circuit for the mixing motorsMove on to Step 1. Mixing motor(s) electrical circuit faulty1. Restore the connections (see Wiring Diagram E6020)
2. Connections correct, right motor defective2. Replace the motor    See in Op. 5040D86 air conditioner right air mixture flap control motor - r r
3. Connections correct, left motor defective3. Replace the motor    See in Op. 5040D84 air conditioner left hand air mixer flap control motor - r r
5HEATER HYDRAULIC CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check:

  • that there is no air in the heater circuit
  • the seal of the supply and return pipes
Move on to Step 1. Air in the circuit1. Bleed the heater circuit
2. No pipe seal2. 1. Renew the seal, if necessary, replace the pipe     See in Op. 5040A50 PIPE from compressor to air conditioner condenser - R and R
6HEATER RADIATOR CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the efficiency of the heater radiatorMove on to Step Radiator dirty or obstructedClean the radiator, if necessary, replace it    See in Op. 5040C50 Air conditioning HEATER RADIATOR - R.R.
7CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present