371582 - N36 THE NAVIGATOR DOES NOT WORK

the navigator is integrated in the Connect
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
0PRELIMINARY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the NAV CD is inserted correctly and recognized by the Connect.Move on to Step 1. NAV CD not inserted1. Insert the NAV CD
2. NAV CD not recognized2. Replace the NAV CD
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment to the diagnostic connector and check the following at the Connect NodeIn errors ambient

  • that there are no faults
Move on to Step Presence of faultsContinue following the instructions for the diagnostic equipment.
2ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Remove the Control Panel, remove the Connect and check that the Connector for the aerial is correctly fitted in its housing (Wiring Diagram ) E4091 CONNECT Move on to Step Connector disconnected from the Connect.Fit the connector in its housing (Wiring Diagram ) E4091 CONNECT
3ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity/insulation of the connecting cables between the Connect and the G.P.S. aerial (Wiring Diagram ) E4091 CONNECT Move on to Step Aerial lead faultyRestore the electrical connection (Wiring Diagram ) E4091 CONNECT
4CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the aerial mounting.