| STEP | OPERATIONS TO BE CARRIED OUT | TEST RESULTS | 
|---|
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Connect the Examiner diagnostic equipment to the diagnostic connector and check the following at the CAN: no control unit not activated;that there are no faulty control units;no control unit with faulty CAN line;
 | Move on to Step | Presence of faults | Continue following the instructions for the diagnostic equipment | 
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Keeping the Examiner diagnostic equipment connected to the diagnostic connector, check the following at the instrument panel node:in active diagnosis ambient the operation of the panel lighting.
 | Move on to Step | The instrument panel does not light up | Replace instrument panel    See in Op.   5560B11  ANALOGUE CONTROL PANEL - R.R. or Replace | 
| 3 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the fault is no longer present |  | Fault persists | Replace body computer    See in Op.   5505A32  BODY COMPUTER - R.R. |