841005304 - E6015 ADDITIONAL HEATER OPERATIONAL DESCRIPTION
Operational Description
The Webasto additional heater control unit M075 receives a supply at pin 1 of connector B from the line from the battery (+30) protected by fuse F62 of the luggage compartment junction unit B045. The Body Computer M001 receives the engine coolant temperature and engine rpm ignals via the C-CAN (pins 32 and 33 of connector B). See E5050 DIESEL ENGINES ELECTRONIC MANAGEMENTThe info-telematic control unit M065, supplied by the line protected by fuse F39 of the junction unit under the dashboard B002, transmits the settings (timer) and the commands, via the B-CAN (pins 1 and 3 of connector B) and via the serial line (pin 10 of connector F) to the climate control system control unit M070, at pins 5 and 16 of connector B and pin 4 of connector A, respectively.On receiving positive signals from the climate control system control unit M070, the Webasto control unit M075 activates the engagement in:Parking Heater mode, at pin 1, of connector A;Additional Heater mode, at pin 3, of connector A;Rest mode, at both pins. |