371558 - N29 INFO TELEMATIC NODE NOT WORKING

The Connect is not activated and the climate control system controls are not working
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the diagnostic equipment to the diagnostic connector and check the following at the Connect:In errors ambient

  • that there are no faults
Move on to Step Presence of faults.Continue following the instructions for the diagnostic equipment.
2ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Disconnect the Control Panel at the dashboard and check for a power supply (positive and earth) (Wiring Diagram ) E4091 CONNECT Move on to Step Supply not correctMove on to Step
3ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Disconnect the Connect from its housing and check:

  • the condition of the connection to earth
  • the presence of the supply positive (Wiring Diagram ) E4091 CONNECT
Move on to Step 1. No connection to earthMove on to Step
2. No power supply positiveMove on to Step
4ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity/insulation between:

  • Connect earth contact and dedicated earth point;
  • Connect positive contact and Dashboard Junction Unit;
  • Dashboard Junction Unit contact and dedicated fuse (Wiring Diagram ) E4091 CONNECT
Move on to Step 1. Connection to earth broken/not insulated1. Restore the electrical connection to earth (Wiring Diagram ) E4091 CONNECT
2. Positive connection broken/not insulated2. Restore the electrical connection to the positive (Wiring Diagram ) E4091 CONNECT
3. Dashboard Junction Unit interrupted internally3. Replace the Dashboard Junction Unit    See in Op. 5505A10 Junction UNIT - R.R.
5ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity/insulation of the electrical connections between the Connect and Control Panel (Wiring Diagram ) E4091 CONNECT Move on to Step Connections broken/not insulatedRestore the electrical connection. (Wiring Diagram ) E4091 CONNECT
6CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the Connect unit    See in Op. 5580P20 CONNECT CONTROL UNIT - R.R.
7CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentFault persistsReplace the Control Panel