80260 - 7025C40 Fuel filler flap control MOTOR - R.R. and check closing supply line

Removing ( Refitting ) - Disconnect the negative battery terminal.1. Open the fuel filler flap.2. Undo the fixing bolts (2a) and remove the motor complete with bracket (2b) from the housing.3. Disconnect the electrical connector.
DescriptionConnector
3 Fuel filler flap lock geared motorN058
1. At the bench, undo the fixing bolts (1a) and separate the motor (1b) from the mounting bracket (1c).
Refitting ( Removing ) - Assembly the motor and the mounting bracket and tighten the fixing bolts.- Connect the electrical connector for the fuel flap motor complete with bracket.
DescriptionConnector
.Fuel filler flap lock geared motorN058
- Fit the fuel flap motor in the housing and secure it using the bolts.- Close the fuel filler flap.- Connect the negative battery terminal.