850422 - 1048A50 air inlet pipe to turbocharger - r + r
Removing ( Refitting ) See in Op. 7055B54 PROTECTION/GUARD under engine - R.R.1. Disconnect the air pipe from the lower resonator (1a) and from the turbocharger (1b).
- Lower the vehicle. See in Op. 7040D50 ENGINE COMPARTMENT UPPER SOUND INSULATION SHIELD - R.R. See in Op. 1016A10 SOUND-PROOFING COVER - R.R. See in Op. 1048B44 RIGID air supply PIPE from heat exchanger to intake manifold - R.R. See in Op. 1048A56 UPPER RESONATOR - R.R.1. Undo the fixing bolt (1a), disconnect the pipe from the air flow meter (1b) and then remove the air inlet pipe (1c).
Refitting
(
Removing
)
- Clean the air flow meter thoroughly to avoid damaging the sensitive element.- Fit the air inlet pipe and connect it to the air flow meter.- Tighten the bolt fixing the mounting bracket. See in Op. 1048A56 UPPER RESONATOR - R.R. See in Op. 1048B44 RIGID air supply PIPE from heat exchanger to intake manifold - R.R. See in Op. 1016A10 SOUND-PROOFING COVER - R.R. See in Op. 7040D50 ENGINE COMPARTMENT UPPER SOUND INSULATION SHIELD - R.R.- Raise the vehicle.- Connect the turbocharger and the lower resonator air inlet pipe. See in Op. 7055B54 PROTECTION/GUARD under engine - R.R.